<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-31 14-59-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 53 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.1 kHz -10 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 70 kHz 9557 31,4638
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,4 dBr 7,48 dBr 8,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 14:59, 31.03.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (53 dBuV) Max at: 70 kHz MIN: 5 kHz % above 76 kHz: 31,4638 Acquired: 2025/03/31 14:58:12 Total samples: 9557 Equivalent time: 0:07:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,1 dBr MIN: 6,4 dBr AVE: 7,48 dBr % above 10,2 dBr: 0,0 Last value: 7,9 dBr (2025/03/31 14:58:11) Station: 96.90 MHz, signal: 4/5 (53 dBuV) 14:51 14:52 14:53 14:54 14:55 14:56 14:57 14:58 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality